Transmission of Legionnaires' Disease through Toilet Flushing

Publié le 18 juin 2020
Mis à jour le 7 janvier 2025

We describe 2 cases of healthcare-associated Legionnaires" disease in patients in France hospitalized 5 months apart in the same room. Whole-genome sequencing analyses showed that clinical isolates from the patients and isolates from the room's toilet clustered together. Toilet contamination by Legionella pneumophila could lead to a risk for exposure through flushing.

Auteur : Couturier Jeanne, Ginevra Christophe, Nesa Didier, Adam Marine, Gouot Cyril, Descours Ghislaine, Campèse Christine, Battipaglia Giorgia, Brissot Eolia, Beraud Laetitia, Ranc Anne-Gaëlle, Jarraud Sophie, Barbut Frédéric
Emerging infectious diseases, 2020, vol. 26, n°. 7, p. 1526-1528